| The AccuTrakT family of products offers an integrated solution for the monitoring of process valves. By combining sensors, solenoids, junction housings and local visual position indication in one compact unit suitable for weatherproof and hazardous location service, Westlock offers an extremely efficient and cost effective method of both monitoring and controlling linear valves. |
|
|
| AccuTrakT With Rotary to Linear Converters |
|
 |
|
|
 |
Available for on-off linear valves, modulating control valves and knife gate valves. |
 |
Switch options include Micro-Switch® , MagnumT, MagPACT, GO®, P&F®, and Effector®. |
 |
Housings in aluminum, engineered resin and stainless steel configurations. |
 |
NEMA 4, 4X, 7, 9, rated enclosures with UL, CSA & FM listings for Hazardous Area applications. |
 |
0-100% position transmitters in either resistive or current (4-20mA) configurations. |
| |
|
|
|
 |
|
|
| |
|
|
|
| |
| Magnum Silver Bullet Position Sensor |
|
 |
|
|
 |
SPST/SPDT 600,000 cycle Rhodium or Tungsten contacts. |
 |
5 Years |
 |
Full Metal Jacket, 316 stainless steel. |
 |
Hermetically sealed fully encapsulated switch. |
 |
FM approved as Explosion Proof for Class I, Division 1, Groups A, B,C and D. |
 |
Tungsten contacts rated 3 amps/120 VAC, 1.5 amps/240 VAC, 2 amps/24 VDC. |
 |
Rhodium contacts rated 0.295 amps/120 VAC, 0.15 amps/240 VAC, 1 amp/24 VDC. |
| |
|
|
|
 |
|
|
|
|
|
| Module3 Integrated Linear Valve Monitoring |
|
 |
|
|
 |
SPST/SPDT 600,000 cycle Rhodium or Tungsten contacts. |
 |
High-current hermetically sealed 316 SS Magnum sensor. |
 |
Integrated enclosure, sensors and optional solenoid. |
 |
UL & CSA approved as Explosion Proof for Class I, Division 1, Groups B,C and D. |
 |
Tungsten contacts rated 3 amps/120 VAC, 1.5 amps/240 VAC, 2 amps/24 VDC. |
 |
Rhodiumcontacts rated 0.295 amps/120 VAC, 0.15 amps/240 VAC, 1 amp/24 VDC. |
| |
|
|
|
 |
|
|
|
|
|
|
| AccuTrak 9900 for Sanitary Diaphragm Valves |
|
 |
|
|
 |
Compact 3.39" height (without solenoid) |
 |
Modular |
| |
- Base plate mounted Puck solenoid with QuickSwap twist lock installation
- QuickSwap conventional and network electronic modules
|
 |
Designed for simple installation and maintenance |
| |
- No tool enclosure entry
- Screw on lid
- Easyaccess to terminal strip for internal wiring
- Modular design allows the quick change out of electronics/switch module or solenoid
|
 |
Compatible with all valve stroke sizes and all manufacturers products |
| |
|
|
|
 |
|
|
|
|
|
|
|
| AccuTrak 9881 for Haz. Area Sanitary Diaphragm Valves |
|
 |
|
|
 |
Position monitoring and control of sanitary diaphragm valves in CID1 hazardous areas. |
 |
Hermetically sealed Magnum™ sensors for position sensing. |
 |
Aluminum housing, with polyurethane enamel coating, assures both strength and |
| |
corrosion resistance. |
 |
Touchset™ Triggers with thumbscrew trigger adjustments eliminate set screws and |
| |
provide instantaneous hand setting of position sensors. |
 |
An easily accessible 8-point prewired, numbered and color coded terminal block is |
| |
provided for simplification of wiring. |
| |
|
|
|
 |
|
|
|
|
|
|
|
| D-EPIC Hornet Non-contact HART Enabled Linear Position Transmitters |
|
 |
|
|
 |
HART® enabled analog Output Signal- Two wire 4 to 20 mA current sink |
| |
(current is proportional to the position). |
 |
ESD/PS option provides for a discrete output via the SIS to control an ESD solenoid. |
 |
EXIDA FMEDA suitable for use in SIL3 applications. |
 |
FM approved as Explosion Proof for Class I, Division 1, Groups B,C and D. |
 |
Low copper content aluminum enclosure with polyurethane enamel coating, |
| |
assures both strength and corrosion resistance. |
 |
16 character by two line LCD display visible with optional sight glass window. |
 |
Non-intrusive configuration via Magnetic trigger zones on enclosure &/or HART® communicator. |
| |
|
|
|
 |
|
|
|
|
|
| |
| D-EPIC 360/366 Non-contact HART Enabled Linear Position Transmitters |
|
 |
|
|
|
 |
HART® enabled analog Output Signal- Two wire 4 to 20 mA current sink |
| |
(current is proportional to the position). |
 |
ESD/PS option provides for a discrete output via the SIS to control an ESD solenoid. |
 |
EXIDA FMEDA suitable for use in SIL3 applications. |
 |
FM approved as Explosion Proof for Class I, Division 1, Groups B,C and D. |
 |
Low copper content aluminum enclosure with polyurethane enamel coating or |
| |
316 SS, assures both strength and corrosion resistance. |
 |
16 character by two line LCD display. |
 |
Non-intrusive configuration via HART® communicator |
| |
|
|
|
 |
|
|
|
|
| |
| Back to Top |
|
|
|
| |
|
|
|