Westlock’s family of positioners set the standard for the control of both rotary and linear valves. With a complete range of products from our K10 auto-calibrating electro-pneumatic postioner to our ICoT product line of full functionality smart positoners; we have the product with the best fit for your application |
|
|
| K10 Electro-Pneumatic Positioner |
|
 |
|
|
 |
Fast calibration through a simple pushbutton AutoCal procedure or remote calibration by utilizing |
| |
an infrared handheld. |
 |
Negligible bleed lapped spool and matched sleeve design delivers significant energy savings in |
| |
the form of extremely low air consumption. |
 |
Corrosion resistant engineered resin Nema 4, 4x enclosure standard |
| |
(Explosionproof unit: Aluminum). |
 |
FM & CSA approved as General Purpose NEMA 4, 4X, 7 & 9, Nonincendive for Class I, |
| |
Division 2, Groups A-D, Explosion Proof for Class I, Division 1, Groups C and D or |
| |
Intrinsically Safe for Class I, Division 1, Groups A-D. |
 |
Beacon visual position monitor. |
 |
Integrated position feedback sensor capability. |
 |
Optional high flow transducer. |
| |
|
|
|
 |
|
|
| |
|
|
|
| |
| ICoT 5200 Intelligent Proximity Positioner |
|
 |
|
|
 |
Fast calibration through a simple pushbutton AutoCal procedure. |
 |
Fully parameterized smart positioner allows customization of any parameter via local keypad. |
 |
Non-contact position feedback via integrated Hall Effect sensor. |
 |
Excellent accuracy, linearity, hysteresis and repeatability in both rotary and linear applications. |
 |
Negligible bleed lapped spool and matched sleeve design delivers significant energy savings in |
| |
the form of extremely low air consumption. |
 |
Corrosion resistant engineered resin Nema 4, 4x enclosure. |
 |
FM & CSA approved as General Purpose NEMA 4, 4X, 7 & 9, Nonincendive for Class I, |
| |
Division 2, Groups A-D or Intrinsically Safe for Zone 0, Class I, II & III Division 1, Groups A-G. |
 |
316 stainless steel enclosure available as an option. |
 |
Local LCD display. |
 |
Remote mount capability. |
 |
Beacon visual position monitor. |
 |
Integrated position transmitter. |
 |
Optional high flow transducer. |
| |
|
|
 |
|
|
|
|
|
| ICoT 5300 Intelligent HART Enabled Proximity Positioner |
|
 |
|
|
 |
HART® enabled. |
 |
Fast calibration through a simple pushbutton AutoCal procedure. |
 |
Fully parameterized smart positioner allows customization of any parameter via local keypad |
| |
or HART. |
 |
Non-contact position feedback via integrated Hall Effect sensor. |
 |
Excellent accuracy, linearity, hysteresis and repeatability in both rotary and linear applications. |
 |
Negligible bleed lapped spool and matched sleeve design delivers significant energy |
| |
savings in the form of extremely low air consumption. |
 |
Corrosion resistant engineered resin Nema 4, 4x enclosure. |
 |
FM & CSA approved as General Purpose NEMA 4, 4X, 7 & 9, Nonincendive for Class I, |
| |
Division 2, Groups A-D or Intrinsically Safe for Zone 0, Class I, II & III Division 1, Groups A-G. |
 |
Local LCD display. |
 |
Remote mount capability. |
 |
Beacon visual position monitor. |
 |
Integrated position transmitter. |
 |
Optional high flow transducer. |
| |
|
|
|
 |
|
|
|
|
|
|
| ICoT 5400 Foundation Fieldbus Proximity Positioner |
|
 |
|
|
 |
FOUNDATION Fieldbus™ enabled. |
 |
Fast calibration through a simple pushbutton AutoCal procedure. |
 |
Fully parameterized smart positioner allows customization of any parameter via local keypad or |
| |
fieldbus. |
 |
Non-contact position feedback via integrated Hall Effect sensor. |
 |
Excellent accuracy, linearity, hysteresis and repeatability in both rotary and linear applications. |
 |
Negligible bleed lapped spool and matched sleeve design delivers significant energy savings in |
| |
the form of extremely low air consumption. |
 |
Corrosion resistant engineered resin Nema 4, 4x enclosure. |
 |
FM & CSA approved as General Purpose NEMA 4, 4X, 7 & 9, Nonincendive for Class I, |
| |
Division 2, Groups A-D or Intrinsically Safe for Zone 0, Class I, II & III Division 1, Groups A-G. |
 |
Local LCD display. |
 |
Remote mount capability. |
 |
Beacon visual position monitor. |
 |
Optional high flow transducer. |
| |
|
|
|
 |
|
|
|
|
|
| |
|
|
| |
|
|
|